• AMB CABLES
  • AMB CABLES
  • AMB CABLES
  • AMB CABLES

AMB CABLES

1.  Center Conductor
2.  Dielectric
3.  Outer Conductor
4.  Intermediate Layer 
5.  Outer Shield
6.  Jacket

Features:

  • Excellent shielding effectiveness(>100dB)
  • Ultra-low loss
  • High phase and amplitude stability 
  • Excellent durability
  • Superior mechanical strength
  • longerservice life
  • AMB CABLES
  • AMB CABLES

Standard Specifications

 
Type AMB-460 AMB-520 AMB-630
Physical and Mechanical Specifications
Center Conductor (mm) 1.02 1.29 1.57
Dielectric (mm) 3.05 3.9 4.72
Outer Conductor (mm) 3.25 4.15 4.96
Intermediate Layer (mm) 3.49 4.28 5.1
Outer Shield (mm) 4 4.73 5.55
Jacket (mm) 4.6 5.2 6.2
Minimum Bending Radius (Installation, mm) 20 25 31
Minimum Bending Radius (Repeated, mm) 46 52 62
Weight (g/m) 50 60 85
Temperature Range -55°C ~ 200°C (-67°F / 392°F)
Electrical Specifications
Impedance (Ohms) 50 50 50
Velocity of Propagation 76% 76% 76%
Dielectric Constant 1.73 1.73 1.73
Shielding Effectiveness >100 dB >100 dB >100 dB
Operating Frequency (GHz) 26.5 26.5 18
Voltage Withstand (DC) 1000 1500 2000
Peak Power (kW) 2.5 5.6 10
Attenuation and Average Power Attenuation(Typical@25ºC)& Power(VSWR 1:1 ; 40ºC; Sea Level)
Frequency (MHz)  dB/100m kW  dB/100m kW  dB/100m kW
300 19.22 1.047 15.01 1.338 12 1.892
1000 35.37 0.569 27.67 0.726 22.18 1.024
2000 50.37 0.4 39.47 0.509 31.71 0.716
3000 62.03 0.324 48.67 0.413 39.17 0.58
4000 71.95 0.28 56.52 0.355 45.54 0.499
6000 88.78 0.227 69.87 0.288 56.43 0.403
8000 103.16 0.195 81.31 0.247 65.79 0.345
12000 127.67 0.158 100.88 0.199 81.88 0.277
18000 158.35 0.127 125.51 0.16 102.23 0.222
26500 194.93 0.103 155.04 0.13 - -